Position Overview
Summary Click on Learn more about this agency button below to view Eligibilities being considered and other IMPORTANT information. The primary purpose of this position is To operate dual fuel high pressure boilers that produce steam and high temperature hot water, to operate electric and gas engine driven chillers and to operate a 4.6 Megawatt cogeneration facility which produces electricity from high pressure natural gas of #2 fuel oil. Additionally, this position performs preventive maintenance. Responsibilities Operate and maintain a 4,600 kw combustion turbine generator (CTG) with a Heat Recovery Steam Generator (HRSG) including generation of electricity to supply the Base. Starts, operates, adjusts, and stops multiple fuel power boilers fueled by fossil fuel and natural gas or a combination of these fuels, steam driven turbines, pumps, auxiliary pollution control and other equipment in high pressure steam central boiler plant. Starts, operates, adjusts, and stops multiple fuel hig...